1 877 524 8100
- Locates faults for opens, shorts, bridged taps, split and re-split pairs, water, chafing damage, coax crimps and splices, shunt faults, splitters, series resistive faults, and any impedance or loop resistance affecting fault
- Micro Fault Locating: two modes designed to pin-point small faults that are easy to miss on a full TDR trace, particularly on long coax cables
- Stores 32 traces and instrument setups and 64 cable types with their impedance and velocity
- Setup Wizard for step-by-step guided startups and one-button Context Sensitive Help for all menus and functions
- Network TDR, includes BNC and RJ-45 connectors, Telco Test leads and F-to-alligator clips test lead
- Includes hard  carrying case (6015-1003)
2.2 lb (1 Kg) with batteries and belt case
Size:
8.5 x 4.3 x 2.25 in (216 x 109 x 57 mm)
Range:
0 - 20,000 ft (5,000 m) @ VF = 0.999 c
Display Resolutions:
1 in (2.54 cm) 0 - 5,000 ft 5 ft 4 in (1.63 m) 5,000 - 10,000 ft or 0.1% of span distance with Accuracy of <0.2% + 1 in (2.54 cm) + VoP uncertainty
Measurement Speed:
1-2 updates/second depending on range
Impedance Range:
1-1 KΩ with resolution: 0.1Ω and Accuracy: <2% @ 40< Z <120
Impedance Plotting Scales:
0 - 20, 50, 100, 200, 500 and 1,000 Ohms
Impedance Formats:
Ohms
Output Power:
0.4 volts peak-to-peak
Power Requirements:
90 - 240 VAC, 50-60 Hz for AC operation or battery charging
Velocity of Propagation:
0.20 - 0.99c wi