1 877 524 8100
- EMI shielded interior protects against RF interference and emissions
- Includes a dark grey ABS plastic case and enhanced keypad
- Redesigned belt case with an accessories pouch and protection for connectors
- Coax and twisted pair testing using same TDR (all types of coax, OSP, twisted pairs [CAT 2 to CAT 6A], and single wires in bundles or harnesses)
- Accurate and clearer trace indication of faults with MicroFault locating for finding even small coax kinks
- Has data transfer abilities: saves, uploads, and emails traces and can upload, download, and customize cable lists
- Saved traces are also saved setups for recall
- Shows reverse ingress or cable signal
- TDR frequency does not interfere with cable signal
- Isolate drop or pairs quickly using Tone function
- Setup Wizard makes training interactive
- E20/20 unit weighs only 2 lb and can be worn on a belt
This kit (6021-5154) includes a ATA 300 catagory 1 rated hard case, connector test leads for pin and socket sizes 12, 16, 20, and 22. coaxial cable with BNC connectors, BNC-to-Alligator clips, RJ45 Cat 5 test lead, AC adapter/charger, USB cable, quick start guide, basic userâs guide, calibration certificate with data, and a CD with operating manual, ETDR PC Vision⢠software, and training presentation.
2.2 lb (1 kg) with batteries and belt case
Dimensions:
8.5 x 4.3 x 2.25 in (216 x 109 x 57 mm)
Maximum Ranges:
20 Kft (5 Km) @ 0.99c or 14 Kft (3300 m) @ 0.66c
Minimum Range:
0 - 10 ft (0 - 2 m)
Range Scales:
11 selectable ranges
Range Acc:
<0.2% ±1 in (2.5cm) + VF uncertainty
Z Accuracy:
<2% (cable Z=45 to 125Ω)
Resolution:
0.5 in on 10 ft range scale or 10 ft zoom (8 mm on 2 m range scale or 2 m zoom)
Dead Zone:
zero on any range setting
Z-Ranges:
20, 50, 100, 200, 500, & 1,000 Ohms
Cursors:
2 independent and differential reading
Memory:
32 traces with 1920 data points (feet), 2000 data